ANALISA TURUNNYA KUALITAS STERILISASI PADA ULTRAVIOLET WATER STERILIZER DI MT. DRAGONARIA DENGAN METODE FAULT TREE ANALYSIS

  • Aditya Arin Sasongko
  • Abdi Seno PIP Semarang
  • Andy Wahyu Hermanto PIP Semarang

Abstract

Ultraviolet water sterilizer is a long cylindrical device used for the sterilization of water into  drinkable water. Ultraviolet water sterilizer has two main parts: an adapter and UV tubes. The  adapter serves to drain ration electricity in accordance with the voltage and current required by  ultraviolet water sterilizer. Tubes UV is containing lamps germicides where light is equipment  major unruk make the water drinkable and the water will flow along the ultraviolet rays, so that the  water flowing in the tube is passed through the sterilization process with ultraviolet rays so that the  water unfit for consumption. The problems that the authors take in this study are the factors that  affect the declining quality of sterilization, the impact of what happens when the quality of  sterilization decreased, and what efforts made to keep the quality of sterilization is not decreased.  The method used is the method of fault tree analysis, a method to find the root of the problem  by using a fault tree and simple logic gates to help determine the basic problem. Fault tree analysis  method consists of a top event, intermediate event, and basic event where all three events are  interrelated to form the fault tree that can be seen cause and effect. Data collected through  observation, interviews, and literature directly to the subject related to the factors, the impact, as  well as the efforts of the decline in the sterilization process to the sterilizer in order to improve the  quality of drinking water.  The cause of the decline to the sterilizer sterilization process in order to improve the quality  of drinking water in MT. Dragonaria that dirty filters, dirty water tubes, and the dirty germicidal  lamp or berdampaknya resulting in less fresh water, complaint against the company, as well as the  ship operational cost is reduced. Therefore made some efforts to improve the quality of the results  of sterilization including cleaning filters, cleaning water tubes, and also clean the germicidal lamp,  as well as auxiliary engine checks periodically so that the quality of sterilization can be increased. 

Downloads

Download data is not yet available.

References

Effendi, Hefni. 2003. Telaah Kualitas Air
Bersih. Jakarta: Kanisius
Engine Log Book Maintenance of Ultraviolet
Water Sterilizer JSA – 3000
Horne, M. Mima. 2008. Keseimbangan Cairan
Elektrolit & Asam Basa. Jakarta
Instruction Manual Book of Ultraviolet Water
Sterilizer JSA – 3000
Kristiansen, Svein. 2005. Maritime
Transportation Safety Management
and Risk Analysis. New York
Aditya Arin Sasongkoa, Abdi Senob, Andy Wahyu Hermantoc
1632
Peraturan Pemerintah Nomor 82 Tahun 2001
Peraturan Menteri Kesehatan RI Nomor
173/Men.Kes/per/VII/1997
Rustiawan, Dede. 2010. Praktis Belajar Fisika.
Jakarta : Visindo
Sugiyono. 2009. Metode Penelitian Kuantitatif
Kualitatif dan R&D. Bandung:
Alfabeta
Suripin. 2002. Pelestarian Sumber Daya
Tanah dan Air. Yogyakarta
Swain, Helen. 2008. Prinsip-prinsip Sains
Untuk Keperawatan. Jakarta:
Erlangga
Published
2017-05-31
How to Cite
Aditya Arin Sasongko, Abdi Seno, & Andy Wahyu Hermanto. (2017). ANALISA TURUNNYA KUALITAS STERILISASI PADA ULTRAVIOLET WATER STERILIZER DI MT. DRAGONARIA DENGAN METODE FAULT TREE ANALYSIS. Dinamika Bahari, 7(2), 1622-1632. https://doi.org/10.46484/db.v7i2.39